Low voltage ZR-W type switchgears
The ZR-W system switchgears are designed for distribution of electricity at each level, as well as control and protection of electrical devices against short-circuit and overload effects. They can be used as primary switchgears, sub-distribution boards, or as control cabinets.
Their universal configuration enables the use of ZR-W switchgears in the following branches of industry:
chemical / petrochemical,
pharmaceutical,
power plants and CHP plants,,
heavy industry: mines, steel plants, coking plants,
light industry: paper, textile, domestic appliances manufacturing.
And in infrastructure:
data centres,
airports,
office buildings,
shopping centres,
hospitals.
Czytaj wiecej >Description:
Compliance with standards:
The ZR-W type switchgear meets the requirements of the following standards:
- PN-EN 61439-1 - „Low-voltage switchgear and controlgear assemblies. General rules”,
- PN-EN 61439-2 - „Low-voltage switchgear and controlgear assemblies. Power switchgear and controlgear assemblies.”,
- PN-EN 60529 - „Degrees of protection provided by enclosures (IP Code)”,
- PN-EN 62262 - „Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code)”
Electrical data: | |
Rated insulation voltage | 690 V / 1000 V / 1500 V1) AC up to 1500 V DC |
Rated connection voltage | 400 V / 500 V / 690 V / 1000 V2) AC up to 1200 V DC |
Test impulse withstand voltage | 8 kV |
Rated frequency | 50 Hz |
Rated current of the switchgear | from 1000 to 6300 A |
Rated short-time withstand current | up tp 105 kA (1s) |
Rated peak withstand current | up to 231 kA |
Resistance to internal arcing | 105 kA / 1s |
1) Up to 1500 V AC in custom design.
2) Up to 1000 V AC in custom design.
Mechanical data: | |
Dimensions | Width from 400 to 1200 mm Height 1900 / 2200 mm Depth 600 / 800 / 1000 mm |
IP degree of protection | from IP20 up to IP54 |
IK degree of protection | up to IK 10 |
Form of compartments (depending on bay type) |
from 2A to 4B |
Surface protection | Framework: 2.5 mm zinc and galvanized steel sheet Covers (doors): 1.5/2 mm painted sheet 3) Font panels: 1.5 mm painted steel sheet |
Powder painting | RAL 7035 as standard, other colours on request |
Plastic components | Halogen-free, self-extinguishing, fire-resistant, CFC-free |
3) Other design technology to be agreed with the manufacturer.
Service conditions: | |
Ambient temperature - Lower limit of ambient temperature - Upper limit of ambient temperature - Average daily temperatures over 24 hours |
-5°C (- 25°C)4) + 40°C from -5°C to 35°C |
Relative humidity | up to 50% (at a temp. 40°C) |
Installation altitude | up tp 1000 m a.s.l. |
Atmosphere at the place of installation | free from chemically aggressive and conducting dust, fumes and gases |
4) Depending on the devices used.
At the customer's request it is possible to design a switchgear adapted to other conditions.